Technical Data

MODEL VTH (Vertical Cryogenic LNG Thermosiphon Tanks)                                                                             
CONFIGURATION    Vertical
STANDARD CAPACITIES    7.6 KL, 20 KL, 30 KL, 56 KL, 114 KL, 256 KL 
DESIGN TEMPERATURE -196 °C to 55 °C
APPLICABLE DESIGN CODES 

ASME, EN13458-2, PED and Other International Codes
CE Marking & U Stamp offered on request

INSULATION Perlite in Vacuum, Multi Layer Super Insulation (optional)
RAW MATERIALS

Inner Vessel & Piping: Stainless Steel 
Outer Vessel : Carbon Steel

NO. OF THERMOSPHION POTS   1,2,3 & more on request